ASPK 2 automation controlling a municipal pumping station with 2 pumps
Out of stock
Regular price
£2,406.00
contains TAX
Couldn't load pickup availability
Controlling a municipal pumping station with two pumps is characterized by a separate level of pump switching and switching off, which allows you to properly regulate the level of retention, and with the switching on the second pump, the alarm signaling is attached. This is due to the emergency need to get rid of an increased amount of sewage from the tank during, for example, an additional influx or leakage from the rainwater sewage system. Although this is not an unheard of, the sewage pumping stations are usually designed for the maximum expenditure on one working pump and the other remains in the reserve. This is due to their frequent and long -term work and thus the need to have a reserve. Therefore, we use in our ASPK control wardrobes sfour -level termination:
Alarm - level of switching on a second pump and alarm alarm signaling.
Start - level of switching on the first pump in automatic mode.
Stop - Pump switching level in automatic mode after emptying the tank.
Drywood -The lowest level indicating a insufficient liquid level for cooling pump engines as well as the risk of them to be announced.
In manual mode, it is possible to pump the liquid to the dry -working level, while the pump is switched on only using the Start buttons on the operator panel. The alarm works regardless of the car mode - manual.
Between the auto and manual modes is the "0" position causing all control and notifying functions to be turned off. This is not tantamount to cutting off the power supply, for this the main switch is used!
Wardrobe equipment:
Non -flammable polyester housing with cable chokes
CREMBER WITH OPERATOR PANEL
Main switch
Differential-current circuit breaker
Setting motor switches for each pump
Control modes: automatic - 0 - manual
Alternating work of two pumps, in the event of a failure, the other completely takes over her work
At continuous operation of the pump over 20 minutes, the pumps are converted
For pumps with a power up to 4kW direct start, for pumps above 4kW as standard Star start-tire boat y/δ. Starting via Soft-Start is valued individually
CR3.1 module for the T1T2 thermal circuit and a possible leak probe
Working time for the pump (LCP)
230 V service socket (GN230)
Signaling of the level of controls on the panel
Four control levels: Suchobieg - Stop - Start - Alarm
Four controls: Suchobieg - STOP - START - ALARM
Optical-acoustic signaling rooster
Key closing
Water and dustproof housing, resistant to weather conditions
Optional: heater with thermostat (GT), Aggregate-0-Sieć socket (GNAS)
Cokół to choose from the list:
Version without a pedestal,
with a dugged plug
or with a plinth for mounting on the tank plate.
The ASPK control wardrobe does not contain swimmers that can be purchased separately. Recommended ZSP-4 level signaling set.
If you do not find the right control automation, please contact us, we will try to offer you the right solution.