PSO -A sewage pumping station Ø1000 - variant A

Out of stock
Regular price £1,887.00 contains TAX
Number of pumps
Diameter of the vertical and outlet
Tank height

Sewage pumping station EM4IS PSO, called "housing estate" is a slightly larger version of the backyard pumping station, in which a larger diameter/retention tank (Ø1000 mm int.) has been used, which allows the installation of two alternating pumps. Thanks to this solution, we get a pumping station with greater capacity and much more reliability. In the event of a failure of one of the pumps, we can take it out to the service, and the pumping station will continue to operate on one pump, ensuring the total covering of sewage pressing from a large multi -family house, small company, workshop, restaurant. e.t.c.

The difference between a home and housing pumping stations is a conventional matter and depends on the type and parameters of the pumps used, the bandwidth of the discharge pipelines and the version of the control used. EM4IS PSO housing estate pumping stations, they can serve both individual houses as well as their clusters, tenements, production plants and entire housing estates.

Advantages of PSO-B sewage pumping station

  • Simple construction modular - all elements (except for the tank) are remedial or replaceable, thanks to which it is possible to easily service,
  • Main components supported from the level - knob knobs for cutting down the cover, pump pulled out for a stainless chain, swimming swimmers pulled out on a stainless chain - This is important That in the event of a failure it is not necessary to enter the tank flooded with sewage!
  • Pumps lowered for a stainless chain, not for pieces of the discharge vertical or nylon links,
  • Gravitational ventilation - ensuring the removal of accumulating toxic and hazardous gases such as hydrogen sulfide or methane,
  • Corrosion resistance - Only highly corrosion -resistant materials, PE polyethylene, stainless steel or powder -painted cast iron are used.

PSO-A municipal sewage pumping station includes:

  1. PEHD tank with an internal diameter Ø1000 mm and height to choose from the list,
  2. Number of connections to pumps to choose from the list,
  3. Discharge risers, a feedback fitting and a diameter outlet to choose from the list,
  4. In the version AND For each of the freestanding pumps at the bottom: a ball check valve, a shut -off ball valve (DN50) or a V -shutter (DN65 and DN80), pump chain.

The pumping station does not contain a pump or control that should be properly selected and purchased separately.

If the selected configuration is not available immediately, the delivery time is about 10 business days.

It is possible to order the service: making the PVC160 inflow holes at the construction site (matching to existing conditions) and connecting pipelines to the pumping station, connecting the control, starting the pumping station and training - Ask for details!